• Hamon Air Inlet Louver for Cooling Tower
  • Hamon Air Inlet Louver for Cooling Tower
  • Hamon Air Inlet Louver for Cooling Tower
  • Hamon Air Inlet Louver for Cooling Tower
  • Hamon Air Inlet Louver for Cooling Tower
  • Hamon Air Inlet Louver for Cooling Tower

Hamon Air Inlet Louver for Cooling Tower

After-sales Service: 1 Year
Warranty: 1 Year
Ventilation Mode: Natural Ventilation
Material: PVC
Air Contact Form: Wet and Dry
Air Contact Way: Open
Samples:
US$ 3/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Tower Shape
Square
Noise Level
Ultra Quiet
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Size
2000*500*177 mm
Transport Package
Wooden Pallet, Wooden Case
Specification
Width 165mm*Length: customized
Trademark
LATINO
Origin
China
Production Capacity
100000/Month

Product Description

Hamon Air Inlet Louver for Cooling Tower


Air Inlet Louver For Cooling Tower
 

Air Inlet Louver For Cooling Tower are designed to capture large water droplets caught in the cooling tower air stream. The eliminators prevent the water droplets and mist from escaping the cooling tower. Eliminators do this by causing the droplets to change direction and lose velocity at impact on the blade walls and fall back into the tower. Efficient drift eliminators will keep drift losses to less than .001% of the re-circulating water flow rate.

 

Drift eliminators are used to control water loss from a cooling tower by limiting the amount of circulating water droplets that are emitted with the exhaust air of the tower. Since drift droplets contain the same chemical and particulate matter of the circulating water from which they originate, they can cause numerous detrimental effects on surrounding equipment and the environment. The cooling tower industry uses drift rate to compare drift eliminator performance, a relationship that correlates droplet capture efficiency to the water circulation rate in a tower. LATINO's drift eliminators are specifically designed to achieve maximum drift removal efficiency in both crossflow and counterflow tower applications with various product options available to minimize pressure drop, drift loss, cost, or a combination of all three.

       Air Inlet Louvers prohibits the light of the sun from entering the cooling tower basin. Installing air inlet louvers helps control the growth of algae. Controlling the light and limiting algae growth means lowering chemical costs.

Air Inlet Louvers also help lower the amount of splash-out from the cooling tower. This reduces the amount of water and chemical needed to run the cooling tower efficiently. Also, you will experience easier basin access and removal.

Without proper care and maintenance the air inlet louvers in cooling towers with counterflow can sometimes become scaled. If this happens it reduces cooling tower efficiency.

        Louvers that are scaled lessen the air flow to the unit thus lessening the efficiency.


Hamon Air Inlet Louver for Cooling Tower

Hamon Air Inlet Louver for Cooling Tower

 

Hamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling TowerHamon Air Inlet Louver for Cooling Tower

 

 

 

 

 

 

 

 

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now